Test Code 21OH 21-Hydroxylase Antibodies, Serum
Additional Codes
EPIC Order Code: LAB3603
Ordering Guidance
Testing for autoantibodies against 21-hydroxylase is recommended following confirmation of adrenal insufficiency to help differentiate between causes of primary adrenal insufficiency
Shipping Instructions
Ship specimen frozen on dry ice
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL Serum
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Useful For
Investigating adrenal insufficiency
Aiding in the detection of those at risk of developing autoimmune adrenal failure in the future
Method Name
Enzyme-Linked Immunosorbent Assay (ELISA)
Reporting Name
21-Hydroxylase Ab, SSpecimen Type
SerumSpecimen Minimum Volume
Serum: 0.2 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Frozen | 14 days |
Reject Due To
| Gross hemolysis | Reject |
| Gross lipemia | Reject |
| Gross icterus | Reject |
Reference Values
Negative
Interpretation
This is a qualitative test. A positive result indicates the presence of autoantibodies to 21-hydroxylase and is consistent with Addison disease.
Utilizing an index value of <45 as a negative cutoff, this assay has a clinical sensitivity and specificity of 87.0% (95% CI: 79.4%-92.2%) and 99.3% (95% CI: 97.5%-99.8%), respectively.
Day(s) Performed
Wednesday
Report Available
3 to 9 daysPerforming Laboratory
Mayo Clinic Laboratories in Rochester
CPT Code Information
83516
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| 21OH | 21-Hydroxylase Ab, S | 85363-0 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| 607788 | 21-Hydroxylase Ab, S | 85363-0 |