Sign in →

Test Code 21OH 21-Hydroxylase Antibodies, Serum

Additional Codes

EPIC Order Code: LAB3603


Ordering Guidance


Testing for autoantibodies against 21-hydroxylase is recommended following confirmation of adrenal insufficiency to help differentiate between causes of primary adrenal insufficiency



Shipping Instructions


Ship specimen frozen on dry ice



Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL Serum

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Useful For

Investigating adrenal insufficiency

 

Aiding in the detection of those at risk of developing autoimmune adrenal failure in the future

Method Name

Enzyme-Linked Immunosorbent Assay (ELISA)

Reporting Name

21-Hydroxylase Ab, S

Specimen Type

Serum

Specimen Minimum Volume

Serum: 0.2 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Frozen 14 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject

Reference Values

Negative

Interpretation

This is a qualitative test. A positive result indicates the presence of autoantibodies to 21-hydroxylase and is consistent with Addison disease.

 

Utilizing an index value of <45 as a negative cutoff, this assay has a clinical sensitivity and specificity of 87.0% (95% CI: 79.4%-92.2%) and 99.3% (95% CI: 97.5%-99.8%), respectively.

Day(s) Performed

Wednesday

Report Available

3 to 9 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

83516

LOINC Code Information

Test ID Test Order Name Order LOINC Value
21OH 21-Hydroxylase Ab, S 85363-0

 

Result ID Test Result Name Result LOINC Value
607788 21-Hydroxylase Ab, S 85363-0