Test Code AMLPC Amylase, Pancreatic Cyst Fluid
Additional Codes
EPIC Order Code LAB3863
Reporting Name
Amylase, Pancreatic CystUseful For
Aiding in distinguishing between pseudocysts and other types of pancreatic cysts when used in conjunction with imaging studies, cytology, and other pancreatic cyst fluid tumor markers
Performing Laboratory
Mayo Clinic Laboratories in Rochester
Specimen Type
Pancreatic Cyst FluidOrdering Guidance
For other body fluid specimens (eg, peritoneal, pleural), order AMBF / Amylase, Body Fluid. Testing will be changed to AMBF if this test is ordered on any fluid other than pancreatic fluid.
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Container/Tube: Plain vial
Specimen Volume: 1 mL
Additional Information: A minimum of 0.5 mL is required for testing; specimens less than 0.5 mL may be rejected.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Pancreatic Cyst Fluid | Frozen (preferred) | 30 days |
| Ambient | 7 days | |
| Refrigerated | 7 days |
Reference Values
An interpretive report will be provided.
Day(s) Performed
Monday through Saturday
CPT Code Information
82150
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| AMLPC | Amylase, Pancreatic Cyst | 48996-3 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| AMYPC | Amylase, Pancreatic Cyst | 48996-3 |
| SITE6 | Site | 39111-0 |
Interpretation
A pancreatic cyst fluid amylase concentration of less than 250 U/L indicates a low risk of a pseudocyst and is more consistent with cystic neoplasms such as mucinous cystic neoplasms (MCN), intraductal papillary mucinous neoplasm (IPMN), serous cystadenomas, cystic neuroendocrine tumor, and mucinous cystadenocarcinoma. High pancreatic cyst fluid amylase values are nonspecific and occur both in pseudocysts and some mucin-producing cystic neoplasms including MCN, IPMN, and mucinous cystadenocarcinoma.
In-house studies showed that using a cutoff value of less than 250 U/L to exclude a pseudocyst has 94% sensitivity and 42% specificity. Cysts with amylase levels of less than 250 U/L included 69% of adenocarcinomas, 31% of intraductal papillary mucinous neoplasia, 55% of mucinous cystadenomas, 64% serous cystadenomas, and 6% of pseudocysts.
Report Available
1 to 3 daysReject Due To
| Gross hemolysis | Reject |
Method Name
Substrate Kinetic
Forms
If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:
-Oncology Test Request (T729)