Sign in →

Test Code CMVQN Cytomegalovirus (CMV) DNA Detection and Quantification by Real-Time PCR, Plasma

Additional Codes

CNE Order Code: CMVDNAQuant


Shipping Instructions


1. Ship specimen frozen on dry ice only.

2. If shipment will be delayed for more than 24 hours, freeze plasma at -20 to -80° C (up to 84 days) until shipment on dry ice.



Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: Lavender top (EDTA)

Submission Container/Tube: Plastic vial

Specimen Volume: 1.5 mL

Collection Instructions:

1. Centrifuge blood collection tube per manufacturer's instructions (eg, centrifuge within 2 hours of collection for BD Vacutainer tubes).

2. Aliquot plasma into plastic vial.


Forms

If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:

-Microbiology Test Request (T244)

-Renal Diagnostics Test Request (T830)

-General Test Request (T239)

Useful For

Detection and quantification of cytomegalovirus (CMV) viremia

 

Monitoring CMV disease progression and response to antiviral therapy

Method Name

Real-Time Polymerase Chain Reaction (RT-PCR)

Reporting Name

CMV DNA Detect/Quant, P

Specimen Type

Plasma EDTA

Specimen Minimum Volume

0.6 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Plasma EDTA Frozen (preferred) 84 days
  Refrigerated  6 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK

Reference Values

Undetected

Interpretation

The quantification range of this assay is 35 to 10,000,000 IU/mL (1.54 log to 7.00 log IU/mL), with a 95% or higher limit of detection at 35 IU/mL.

 

A result of "Undetected" indicates the absence of cytomegalovirus (CMV) DNA in the plasma (see Cautions below).

 

A result of "<35 IU/mL (<1.54 log IU/mL)" indicates that CMV DNA is detected in the plasma, but the assay cannot accurately quantify the CMV DNA present below this level.

 

A quantitative value (reported in IU/mL and log IU/mL) indicates the level of CMV DNA (ie, viral load) present in the plasma.

 

A result of ">10,000,000 IU/mL (>7.00 log IU/mL)" indicates that CMV DNA level present in plasma is above 10,000,000 IU/mL (7.00 log IU/mL), and the assay cannot accurately quantify CMV DNA present above this level.

Day(s) Performed

Monday through Saturday

Report Available

1 to 5 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

87497

LOINC Code Information

Test ID Test Order Name Order LOINC Value
CMVQN CMV DNA Detect/Quant, P 72493-0

 

Result ID Test Result Name Result LOINC Value
601954 CMV DNA Detect/Quant, P 72493-0