Sign in →

Test Code HALO Haloperidol, Serum

Reporting Name

Haloperidol, S

Useful For

Optimizing haloperidol dosage

 

Monitoring patient compliance

 

Assessing toxicity

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum Red


Specimen Required


Supplies: Sarstedt Aliquot Tube 5 mL (T914)

Collection Container/Tube: Red top (serum gel/SST are not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions:

1. Draw blood immediately before next scheduled dose.

2. Within 2 hours of collection, centrifuge and aliquot serum into a plastic vial.


Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Red Refrigerated (preferred) 28 days
  Ambient  28 days
  Frozen  28 days

Reference Values

Haloperidol:

5-17 ng/mL

 

Reduced Haloperidol:

10-80 ng/mL

Day(s) Performed

Tuesday

CPT Code Information

80173

LOINC Code Information

Test ID Test Order Name Order LOINC Value
HALO Haloperidol, S 87550-0

 

Result ID Test Result Name Result LOINC Value
80339 Haloperidol, S 3669-9
169 Reduced Haloperidol 38364-6

Interpretation

Studies show a strong relationship between dose and serum concentration(4); however, there is a modest relationship of clinical response or risk of developing long-term side effects to either dose or serum concentration.

 

A therapeutic window exists for haloperidol, but some patients may respond to concentrations outside of this range. Patients who respond at serum concentrations between 5 ng/mL and 17 ng/mL show no additional improvement at concentrations between 18 ng/mL and 20 ng/mL.(3,5) Some patients may respond at concentrations less than 5 ng/mL, and others may require concentrations significantly greater than 20 ng/mL before an adequate response is attained.

 

Due to interindividual variation, the serum concentration should only be used as one factor in determining the appropriate dose and must be interpreted in conjunction with the clinical status.

 

Although the metabolite, reduced haloperidol, has minimal pharmacologic activity, evidence has been presented suggesting that an elevated ratio of reduced haloperidol-to-haloperidol (ie, >5) is predictive of a poor clinical response.(3,6) A reduced haloperidol-to-haloperidol ratio of less than 0.5 indicates noncompliance; the metabolite does not accumulate except during steady-state conditions.

Report Available

2 to 8 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Method Name

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

Forms

If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.