Test Code HEVQU Hepatitis E Virus RNA Detection and Quantification, Real-Time RT-PCR, Serum


Shipping Instructions


1. Freeze serum immediately, and ship specimen frozen on dry ice.

2. If shipment will be delayed for more 24 hours, freeze serum at -20 to -80° C (up to 35 days) until shipment on dry ice.



Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 1.8 mL

Collection Instructions:

1. Centrifuge blood collection tube per collection tube manufacturer's instructions (eg, centrifuge within 2 hours of collection for BD Vacutainer tubes).

2. Aliquot serum into plastic vial.


Useful For

Virologic detection and confirmation of hepatitis E virus (HEV) infection in individuals who are immunocompromised and are at risk for or suspected to have acute or chronic hepatitis E

 

Monitoring HEV RNA levels and determining eradication of chronic HEV infection in individuals who are immunocompromised

Testing Algorithm

For more information see Hepatitis E: Testing Algorithm for Diagnosis and Management.

Method Name

Real-Time Reverse Transcriptase-Polymerase Chain Reaction (RT-PCR)

Reporting Name

HEV RNA Detect / Quant, S

Specimen Type

Serum SST

Specimen Minimum Volume

0.8 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum SST Frozen (preferred) 35 days ALIQUOT TUBE
  Refrigerated  5 days ALIQUOT TUBE

Reject Due To

Gross hemolysis OK
Gross lipemia OK

Reference Values

Undetected

Interpretation

The quantification range of this assay is 50 to 5,000,000 IU/mL (1.70 log to 6.70 log IU/mL), with a limit of detection (based on a 95% detection rate) of 20 IU/mL (1.40 log IU/mL).

 

An "Undetected" result indicates that hepatitis E virus (HEV) RNA is not detected in the serum specimen (see Cautions). Repeat testing in 1 to 2 months is recommended for those at risk of HEV infection. The limit of detection (based on a 95% detection rate) for this assay is 20 IU/mL.

 

A result of "<50 IU/mL" indicates that the HEV RNA level present in the serum specimen is below 50 IU/mL (1.70 log IU/mL), and the assay cannot accurately quantify the HEV RNA present below this level.

 

A quantitative value (reported in IU/mL and log IU/mL) indicates the HEV RNA level (ie, viral load) present in the serum specimen.

 

A result of ">5,000,000 IU/mL" indicates that the HEV RNA level present in the serum specimen is above 5,000,000 IU/mL (6.70 log IU/mL), and this assay cannot accurately quantify the HEV RNA present above this level.

 

An "Indeterminate" result suggests the presence of an atypical HEV target sequence. Since the HEV RNA sequence is atypical, repeat testing is unlikely to change this result and therefore is not recommended.

 

An "Equivocal" result indicates that the presence or absence of HEV RNA in the serum specimen could not be determined with certainty due to atypical real-time reverse transcriptase-polymerase chain reaction (RT-PCR) probe reactivity. Submission of a new specimen for testing is recommended.

 

An "Inconclusive" result indicates that the presence or absence of HEV RNA in the serum specimen could not be determined with certainty after repeat testing in the laboratory, possibly due to RT-PCR inhibition. Submission of a new specimen for testing is recommended.

Day(s) Performed

Varies

Report Available

1 to 10 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

87799

LOINC Code Information

Test ID Test Order Name Order LOINC Value
HEVQU HEV RNA Detect / Quant, S 69961-1

 

Result ID Test Result Name Result LOINC Value
62929 HEV RNA Detect / Quant, S 69961-1

Forms

If not ordering electronically, complete, print, and send 1 of the following with the specimen:

-Gastroenterology and Hepatology Test Request (T728)

-Microbiology Test Request (T244)